5 TIPS ABOUT ASTM F2170 11 YOU CAN USE TODAY

5 Tips about Astm F2170 11 You Can Use Today

5 Tips about Astm F2170 11 You Can Use Today

Blog Article



ATTAR (Advanced Technology Testing & Research)
44/48 Rocco Dr, Scoresby VIC 3179, Australia
+61 1300 139 155
https://maps.app.goo.gl/RoEp6iupmJCuiUxk6

When it concerns guaranteeing security in industrial, commercial, and property spaces, slip resistance testing is a vital factor. At ATTAR (Advanced Technology Testing & Research), we focus on floor slip resistance testing, concrete moisture testing, and luminance contrast analysis to assist organizations and property owners alleviate risks and comply with safety requirements.

With cutting edge devices such as the pendulum slip test maker and moisture meter for concrete, we provide precise and independent slip testing services across Australia. Our knowledge covers ASTM F2170 compliance, R Ranking evaluations, P Ranking tiles, and more, guaranteeing your floors satisfy the greatest security benchmarks.

Why Slip Resistance Testing is Essential


Slips and falls are among the leading reasons for office and public injuries. Correct slip testing helps determine dangerous surface areas before mishaps take place. Whether you require damp pendulum test examinations or pendulum test for slip resistance, ATTAR provides exact results to enhance safety.

Secret Services Used by ATTAR


1. Floor Slip Resistance Testing

- Pendulum slip test (AS 4663).
- R Ranking and P Ranking tiles evaluations.
- Independent slip testing services for compliance.

2. Concrete Moisture Testing

- Slab moisture test utilizing innovative moisture meter for concrete.
- ASTM F2170 certified evaluations.
- Concrete slab moisture testing to prevent floor covering failures.

3. Luminance Contrast Testing

- Makes sure presence for aesthetically impaired people.
- Complies with Australian ease of access requirements.

4. On-Site & Laboratory Testing

- Slip test device for accurate on-site evaluations.
- Wet pendulum test for wet surface area slip resistance.

Comprehending Slip Resistance Rankings: R Ranking vs. P Score


When carrying out slip resistance testing, two key classifications are used:.

- R Rating (Ramp Test - DIN 51130)
Measures slip resistance under lubricated conditions, commonly utilized in Europe.

- P Ranking (Pendulum Test - AS 4586)
Evaluates dynamic friction using a pendulum test slip resistance maker, extensively embraced in Australia.

ATTAR provides independent slip testing to determine whether your floor covering fulfills the required pendulum rating tiles standards.

The Value of Concrete Moisture Testing


Excess moisture in concrete slabs can result in flooring failures, mold development, and adhesive destruction. Our concrete moisture testing services consist of:.

> ASTM F2170 compliant in-situ relative humidity testing.
> Moisture meter for concrete assessments.
> Slab moisture test to ensure optimal conditions for floor installations.

By spotting moisture problems early, check here we help prevent pricey repairs and guarantee long-lasting flooring efficiency.

Luminance Contrast for Ease Of Access Compliance


Proper luminance contrast is vital for aesthetically impaired people to navigate areas safely. ATTAR evaluates:.

> Stair edges.
> Door frames.
> Handrails.
> Tactile signs.

Our assessments ensure compliance with Australian Special needs Standards (AS 1428.1).

Why Select ATTAR for Slip Resistance & Moisture Testing?


> NATA Accredited (where appropriate).
> Advanced Testing Equipment (pendulum slip test, moisture meters).
> Nationwide Service Protection.
> Quick & Reputable Reporting.

For expert slip resistance testing, floor slip resistance testing, and concrete moisture testing, contact ATTAR (Advanced Technology Testing & Research):.

Address: 44/48 Rocco Dr, Scoresby VIC 3179, Australia.
Phone: +61 1300 139 155.

Typical Applications of Slip Resistance Testing


1. Commercial & Retail Spaces

Shopping center, restaurants, and workplaces require safe floor covering to prevent customer and staff member injuries. Our pendulum slip test ensures compliance with safety regulations.

2. Industrial & Storage Facility Facilities

High-traffic commercial environments require durable, slip-resistant floor covering. ATTAR's slip testing services help preserve workplace security.

3. Healthcare & Aged Care Facilities

Health centers and assisted living home need to reduce slip threats. Our luminance contrast and slip resistance testing guarantee safe movement for patients and personnel.

4. Public Infrastructure

Walkways, train stations, and federal government buildings need independent slip testing to meet ease of access and security standards.

How ATTAR Carries Out Slip Resistance Testing


Action 1: Surface Evaluation

We examine flooring products and conditions (dry, damp, or contaminated).

Action 2: Pendulum Slip Test (AS 4663)

Utilizing a slip test machine, we measure the vibrant coefficient of friction (DCOF).

Action 3: Wet Pendulum Test

Mimics slippery conditions to evaluate real-world slip threats.

Step 4: Reporting & Compliance Certification

Comprehensive reports with R Ranking or P Rating tiles classifications.

The Science Behind Pendulum Slip Testing


The pendulum test slip resistance approach includes a swinging arm with a rubber slider that mimics a foot's movement. The test steps:.

- Slip Possible Worth (SPV).
- Pendulum rating tiles classification (P0 to P5).

Greater rankings (P4/P5) indicate much better slip resistance.

Moisture Testing for Concrete Floors: Avoiding Failures


Moisture-related flooring failures can be expensive. ATTAR's concrete slab moisture testing consists of:.

- ASTM F2170 in-situ RH probes.
- Moisture meter for concrete check.
- Slab moisture test information analysis.

Conclusion


ATTAR (Advanced Technology Testing & Research) is Australia's trusted company of slip resistance testing, floor slip resistance testing, concrete moisture testing, and luminance contrast evaluations. With cutting-edge technology like the pendulum slip test and moisture meter for concrete, we deliver accurate, independent, and certified testing services.

Guarantee your property satisfies safety requirements-- contact ATTAR today:.

44/48 Rocco Dr, Scoresby VIC 3179, Australia.
+61 1300 139 155.

By picking ATTAR, you buy independent slip testing services, pendulum test slip resistance precision, and long-lasting floor security options. Let us help you create safer, compliant, and moisture-resistant environments.

Report this page